Functions of the data logger
Pump 233:
Failure in the power supply
Power supply ON
Failure in the membrane key pad
Operating time elapses
Pump element does not dispense
Reservoir empty
Note: The fault indication LL appears
whenever the solenoid fixed to the stir-
ring paddle has passed the proximity
switch six times . Appearing LL on
the display, the lubrication cycle is
being completed fully. Afterwards, the
control does not switch the pump on
automatically any longer.
Pause time
Residual pause time
System:
Lubrication point or divider valve
blocked
Leakage in the main line from
the pump to the monitored
divider valve
Air entrapments in the grease
Failure in one lube cycle
(depending on the installation
of the monitored divider valve).
Membrane key pad:
Er
Er
Er
Er
Membrane key pad:
No indication
Right segment
illuminated
EP
Circulating segment
Er
LL
PP
rP
Printed circuit board MDF 00
The QUICKDATA centralized lubrication system is monitored, i.e.
events such as malfunctions of the centralized lubrication systems, faults in the elapse of the operating time, low-level
indications, pause times, residual pause times of the pump are displayed in the display window of the membrane key
pad and transferred to the data logger.
Data logger (data memory)
Malfunctions (start, end, duration) in the centralized lubrication system, faults in the elapse of the operating time, low-
level indications (start, end, duration), number of connections and disconnections of the power supply, automatically
triggered lube cycles, manually triggered lube cycles, operating data and customer-related data can be read and
analyzed via laptop, see below diagnostic software QuickData.
Functions, processes, settings, faults or malfunctions of the pump and the system are indicated on the membrane key
pad as follows, also see below: Adjustment and Operation of the Control:
Pump 233 is equipped with a readable data memory
(data logger) QuickData.
The data logger renders information regarding system
settings, events such as low-level indications, mal-
functions, operating times and lubrication cycles.
By means of the Lincoln diagnostic software QuickData
the above mentioned data can be read on a suitable
laptop via an infrared interface, see below Owner Manual
Diagnostic Software - QuickData.
Data Logger
Fig. 3 - Data logger module
4357a01