Subject to change without notice
Owner Manual
Operating Instructions
2.1A-30004-A02
LINCOLN GmbH & Co. KG Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259
Page 7 of 36
Description of the QUICKDATA 233 Centralized Lubrication Pump
The QUICKDATA 233 centralized lubrication pump
- is a compact multiline pump consisting of the following
components:
Housing with integrated motor
Reservoir with stirring paddle and fixed paddle
Data logger (control p.c.b. and readable data memory)
Pump element
Pressure relief valve
Filling device
Electrical connection parts
- can drive up to 3 pump elements with different outputs
- operates according to lubrication cycles (pause and
operating times)
- is equipped with a low-level control
- can supply up to 300 lubrication points depending on the
line lengths
- is designed for the automatic lubrication of the connected
lubrication points
- is designed for the delivery of greases up to NLGI 2 at
temperatures from -25°C to +70°C
- can be used with low-temperature greases down to
temperatures of -40°C
During the operating time the pump dispenses lubricant
to the connected lube points via one divider valve model
SSV...-N and several divider valves model SSV... .
4355a01
Fig. 2 - Components of pump 233
1 - Reservoir
2 - Pump element
3-
Pressure relief valve
4 - Filling nipple, system
Emergency lubrication possible
5 - Filling nipple, pump
6 - Adaptor for piston detector
7 - Display
8 - Momentary-contact switch for
indication or setting of pause
time
9 - Reading window for
data logger
10 - Momentary-contact
switch for additional
lubrication
11 - Membrane key pad
12 - Piston detector
13 - Control p.c.b. with
data logger
14 - Adaptor for power supply
External illuminated
pushbutton
15 - Closure plug for the use
of a pump element
The control and monitoring system consists of:
- control p.c.b. MDF00 with
- built-on data logger module with IR interface
- membrane key pad with display
- IR interface module RS 232 (COM) for laptops without IR
interface
- Software QuickData
- monitored divider valve model SSV...-N with integrated
piston detector, see fig. 20.
Control and monitoring system QuickData
Control p.c.b. MDF 00 with data logger
The control is installed in the housing of the pump
behind the membrane key pad as an integrated printed
circuit board MDF 00 (2, fig. 3).
The data logger (1) is fixed onto the printed circuit board.
1 - Data logger
2 - Control p.c.b.
3 - Infrared interface
Fig. 3 - Control p.c.b. MDF 00 with built-on data logger