Quickdata Quikstop-15 Betriebsanleitung Seite 15

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 14
Subject to change without notice
Owner Manual
Operating Instructions
2.1A-30004-A02
LINCOLN GmbH & Co. KG Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259
Page 15 of 36
4360a01
Fig. 22 - Membrane key pad with display and reading window
1 - Display window
2 - Key for acknowledgment of fault indications
and setting of time (shift key)
3 - Reading window for QuickData data
4 - Key for triggering an additional lubrication and for setting the
time values
Membrane key pad
The membrane key pad serves for:
- displaying functions, faults, low-level indications and time
settings in the display window 1, fig. 22 (display mode)
- setting the pause time (programming mode)
- triggering one or several additional lubrications (opera-
ting mode)
- reading of data and events
Display window of the membrane key pad
4279a00
As soon as voltage is applied (On), the lower right-hand
segment in the display window flashes (pause time
runs).
If the power supply is interrupted during the pause time,
after switching it on again, the pause time continues at
the point of interruption.
Fig. 23 - Green segment, pause time, voltage applied
Fig. 24 - Green circulating illuminated segment, operating time
During the operating time of the pump, a circulating
illuminated segment appears in the display window of
the membrane key pad.
If the power supply is interrupted during the operating
time, after switching it on again, the operating time
continues at the point of interruption.
4209a99
4222a99
Additional lubrication
- is triggered via the key of fig. 25. Press key for more than
2 seconds.
- can be triggered at any time provided that voltage is
applied.
Note: If a malfunction is present (flashing display), first
acknowledge the malfunction, then trigger an additional
lubrication (see fig. 28).
If a fault signal (malfunction) is present, it will be
cancelled whenever the system is operating properly.
Fig. 25 - Key for triggering an additional lubrication
4210a99
Fig. 26 - Display of a fault signal
Monitoring time/ malfunction
If there is no feedback from the piston detector (initiator)
within 30 minutes (monitoring time) from completion of
the pause time or from triggering an additional
lubrication, the pump switches off immediately. The fault
signal * Er * (error) is displayed as a flashing light in the
display of the membrane key pad.
If a malfunction is present, the pump does not switch
on automatically any longer.